Sockets 2 · Beginner · 6 min read

How do you wire several sockets on one circuit?

Loop the cable from one socket to the next, so they are all in parallel on the same breaker. A double socket is two sockets already joined inside. The breaker does not care how many sockets there are, only how many amps they draw together.

One breaker feeds two sockets, with the cable looping from one socket to the next. Tap a socket to plug something in. The current in each piece of cable is shown above it, and the breaker trips if the total is too high. Breaker B160 A0 Aemptyempty

Looping from socket to socket

Sockets on one circuit are wired in parallel, just like lamps. The cable comes into the first socket, and a second cable goes on to the next. At each socket, live joins live, neutral joins neutral and earth joins earth.

Two wires in one terminal

Many sockets have terminals made for two wires, one in and one out. Check the marking before you rely on it.

A short tail

Otherwise, join the incoming, outgoing and a short wire in a connector, and put only the short wire into the socket.

A double socket is two sockets on one plate, already joined inside. You connect it like a single one.

The first cable works hardest

Look at the numbers above the cables in the drawing. The current to every socket further along has to pass through the first piece of cable and the first socket's terminals. Plug a kettle into the last socket, and every connection before it carries that current too.

So a loose screw at the first socket does not just affect that socket. It heats up under the load of the whole row, and if it fails, everything after it goes dead.

Ad300 × 250

How many sockets on one circuit?

The breaker does not count sockets, it counts amps. What matters is how much might be switched on at once. That is why the rules talk about floor area and rooms, not just numbers.

RegionUsual approach
EuropeRadial circuits on 16 A with 2.5 mm² cable. Common practice is a limited number of sockets per circuit and separate circuits per room or area, with big appliances on their own.
UKA 32 A ring circuit for up to about 100 m² of floor, or a 20 A radial on 2.5 mm² for up to about 50 m².
North America15 A or 20 A circuits. Kitchens need at least two 20 A circuits for the counter outlets, and bathrooms their own 20 A circuit.

The UK ring circuit

In a ring, the cable leaves the consumer unit, visits every socket and comes back to the same breaker. Current can reach each socket from both directions, which is why 2.5 mm² cable can sit on a 32 A breaker. A single socket branched off the ring is called a spur. Rings are almost only used in the UK and Ireland.

Common mistakes

  • A loose connection at the first socket. It carries the whole row and can overheat.
  • Extending a socket circuit with thinner cable than the rest.
  • Kettle, toaster and microwave on one counter circuit at breakfast time.
  • Plugging power strips into power strips. Each one adds connections, and none adds capacity.
  • Forgetting to carry the earth on to the next socket.
Try it in the sandboxPut three sockets on one breaker, loop the cable between them and load them up in Simulate.
Open the sandbox
Next · Sockets 3Kitchen and big appliances