How are kitchen appliances wired?
Big appliances such as the oven, hob and dishwasher each get their own circuit, with a breaker and cable sized for their power. Small appliances share the counter socket circuits. A hob needs the most: in Europe often three-phase, in North America 240 V.
Typical values for a home kitchen. The real sizes depend on the appliances, the cable length and your local rules.
Why big appliances get their own circuit
An oven, a hob or a dishwasher can pull 10 A or more for an hour. Put two of them on one socket circuit with a kettle and the breaker trips on a busy evening. Worse, cables and connections run hot for a long time.
A circuit of its own gives each big appliance a breaker and a cable that fit its power. It also means a fault in the dishwasher does not switch off the fridge.
When one live is not enough
Many European homes have three lives: L1, L2 and L3, 400 V between any two. A hob takes a 5-core cable, brown, black and grey lives plus blue and green-yellow, and spreads its rings across the three phases. Each phase only carries part of the load.
Homes get two hots, 120 V each to neutral and 240 V between them. Ranges, ovens and dryers use both hots on a two-pole breaker, so they need half the current they would at 120 V.
Protection near water
Kitchens mix power and water, so the shock protection matters most here. In Europe, the UK and Australia, kitchen socket circuits sit behind a 30 mA RCD. In North America, counter outlets need GFCI protection, and newer codes extend it to dishwashers and other appliances.
Keep sockets away from the sink and the hob, so cables never hang over water or heat.
A way to switch it off
A built-in appliance still needs a way to cut its power, for repairs or in an emergency, without reaching behind it.
- UK: a cooker switch beside the cooker, and a switched fused spur above the counter for each built-in appliance.
- Europe: a plug that can be reached, or the appliance's own breaker in the fuse box, clearly labelled.
- North America: a plug that can be reached, or the breaker, which for some appliances must be lockable.
Common mistakes
- Running a 7 kW hob on a single 16 A circuit. It needs three phases, or a 32 A circuit with thicker cable.
- Putting the dishwasher and the washing machine on one circuit. Both heat water, often at the same time.
- Plugging the fridge into an extension lead behind the units.
- Sockets right above the hob or the sink.