What are bathroom zones?
The space around a bath or shower is split into zones. The closer to the water, the stricter the rules: in zone 0, inside the bath, almost nothing is allowed, and ordinary sockets must stay outside the zones altogether. Every bathroom circuit also needs RCD or GFCI protection.
Why bathrooms have zones
Wet skin conducts far better than dry skin, and in a bath you are often touching water and metal at the same time. A shock that would be unpleasant in the living room can be deadly here. So the closer something is to the water, the stricter the rules.
In Europe, the UK and Australia, the space around a bath or shower is split into zones. North America uses distances from the tub instead. The idea is the same: keep anything you plug in away from the water.
IP ratings
The IP code says how well something keeps out dust and water. The second number is the one that counts in a bathroom.
| Rating | Protects against | Typical use |
|---|---|---|
| IPX4 | Splashing water from any direction | Zones 1 and 2 |
| IPX5 | Jets of water | Zone 1 where a jet can hit it, such as a walk-in shower |
| IPX7 | Being under water for a short time | Zone 0, and only at 12 V |
An X in the first place just means the dust rating was not tested.
The rules around the world
| Region | Sockets | Protection |
|---|---|---|
| Europe | Outside zones 0, 1 and 2, so at least 0.6 m from the bath or shower. Countries can be stricter. | 30 mA RCD on every bathroom circuit |
| UK | At least 3 m from zone 1. Only shaver supply units closer. | 30 mA RCD on every bathroom circuit |
| North America | Not within 3 ft sideways and 8 ft up from the tub or shower. At least one 20 A outlet within 3 ft of the basin. | GFCI on all bathroom outlets |
| Australia and NZ | Zones much like Europe's, with sockets kept out of the zones around the bath and shower. | 30 mA RCD |
Switches, pull cords and bonding
Wall switches go outside the zones, often just outside the door. Inside, a pull-cord switch on the ceiling is the usual answer in the UK: you only touch the insulated cord.
Older installations also joined metal pipes, the bath and radiators together with an earth wire, called supplementary bonding. With RCDs on every circuit and plastic pipes, newer rules often no longer require it, but where it is there, leave it in place.
Common mistakes
- An ordinary socket next to the basin, or an extension lead brought in for a hair dryer.
- A normal ceiling light right above the shower. It needs to be rated for the zone.
- A light switch you can reach from the bath or shower.
- A bathroom circuit without RCD or GFCI protection.